CHLORINE TRIFLUORIDE | ICSC: 0656 |
I M P O R T A N T D A T A |
| |||
PHYSICAL PROPERTIES |
| |||
ENVIRONMENTAL DATA |
|
|||
N O T E S | ||||
Thorough flushing with an inert gas should precede any opening of apparatus that has contained chlorine trifluoride.
Reacts violently with fire extinguishing agents such as water.
The occupational exposure limit value should not be exceeded during any part of the working exposure.
The symptoms of lung oedema often do not become manifest until a few hours have passed and they are aggravated by physical effort. Rest and medical observation is therefore essential.
Immediate administration of an appropriate spray, by a doctor or a person authorized by him/her, should be considered.
Specific treatment is necessary in case of poisoning with this substance; the appropriate means with instructions must be available.
Insufficient data are available on the effect of this substance on human health, therefore utmost care must be taken.
Do NOT spray water on leaking cylinder (to prevent corrosion of cylinder).
Also consult ICSC #0283 : hydrogen fluoride.
|